Helios 3D Update 2024.0.1.5
New Version: 2024.0.1.5
DB Version: 2024.0.1.0
Date: 03/22/2024
Operating System: Windows 8, 8.1, 10, 11
AutoCAD: Autodesk Civil 3D 2021 to 2024
- New: The markers for adjusted conflicts in table placement have been updated. If the conflict persists, the table is marked with a cross in the corresponding color, as before. If the conflict has been resolved, the table is now marked with a colored ellipse instead of a cross.
- New: Strings that are not connected to the grid are now colored red in the drawing and listed as „not connected“ in the electrical structure.
- New: Strings that span two adjacent rows can now be wired via marked row-to-row cable trenches. This allows smaller tables to remain in place without needing to be moved toward the cable trench. A row-to-row cable trench can also be used at the end of the row.
- New: A maximum height difference between two neighboring tables can now be defined in the collision parameters for table placement. The placement algorithm will attempt to align the current table with the previous one by adjusting its height.
- New: A maximum angle transition between two neighboring tables can now be defined in the collision parameters for table placement. The placement algorithm will attempt to respect this when positioning the current table in relation to the previous one.
- New: The table azimuth is now displayed in the tooltip of each table.
- New: During table placement, table blocks are now created directly from the table parameters if the block is not found in the drawing or as an external DWG. Previously, it was necessary to go to the table generator and save the table block there.
- Change: Previously, when a drawing was closed, its data remained visible on some palette pages. Now, all palette pages are cleared when the drawing is closed.
- Change: In the manual table positioning dialog, array definitions that are assigned to the respective requirement type but have not been selected are now also displayed.
- Change: When connecting devices/strings in the manual electrical system, overbooking is now checked against the STC (Standard Test Conditions) values.
- Change: When connecting devices/strings in manual electrics, the selection process now automatically terminates if the target device no longer has available inputs.
- Change: The load factor is now calculated based on STC input values on the manual electrics page.
- Change: In the „Inverter Balancing“ dialog, the load factor is now calculated using STC input values.
- Change: When registering fields, they are no longer registered to multiple areas. Now, either the selection in the tree is considered (Add/Draw), or the smallest surrounding area is determined.
- Change: When entering the name for a newly registered restricted area, a unique name is now suggested.