Helios 3D Update 2026.0.1.2

New Version: 2026.0.1.2
DB Version: 2025.0.1.3
Date: 08/13/2025
Operating System: Windows 8, 8.1, 10, 11
AutoCAD: Autodesk Civil 3D 2021 to 2026


  • New: For module markers within the analysis, a new option has been added that colors the modules based on the maximum distance from their rear edge to the ground, in order to visualize conflicts with the maximum permitted overbuild height.
    The module markers can now also be restricted to either the foremost or rearmost module row.
  • New: A new Excel list can now be generated under “Output” that provides an overview of cable runs (strings to a target device and between devices). This list is intended to replace the old cable report.
  • New: A “Requirement Type” column has been added to the table overview in the bill of materials.

  • Bug: The free assignement of string definitions to a table definition didn’t work as expected, when multiple string definitions existed for a single table variant.
  • Bug: The profiles of the terrain markers could not be saved and were also not initialized correctly.
  • Bug: The terrain markers did not produce any meaningful results.
  • Bug: Renaming fields caused an error if the field boundary was registered as an alignment line.
  • Bug: In the cable trench list, cable articles were displayed multiple times for individual segments.
  • Bug: Missing shadows on tables with complex shadow objects.
  • Bug: When placing tables with an alignment line that lay partially outside the site, under certain circumstances this could lead to misplacement of individual tables or to incorrect gaps in the placement.
  • Bug: In manual electrical configuration, the value for the maximum output power of an inverter/transformer was incorrectly displayed in watts instead of kilowatts. As a result, in case of overbooking it was also not correctly determined whether another device could be connected.
  • Bug: When connecting an inverter to a transformer, the STC power of all strings connected to the inverter was previously always used for calculating the power to be connected.
    This, however, does not work if the inverter was overbooked and the connected STC power thus exceeded the inverter’s maximum output power. In such cases, the calculation now uses the inverter’s maximum output power.