Helios 3D Update 2025.0.1.2

New Version: 2025.0.1.2
DB Version: 2025.0.1.0
Date: 12/09/2024
Operating System: Windows 8, 8.1, 10, 11
AutoCAD: Autodesk Civil 3D 2021 to 2025


  • New: Results can now be inserted into the drawing as an SLD (Single Line Diagram) via the electrical structure tree.
  • New: New dialog for creating/editing selection sets. It is now possible to determine directly via string length/device input settings how the strings fit onto the selected tables.
  • New: A new column has been added to the statistics page. It lists the names of the attributes that can be replaced with the values from the second column using the new „Assign Attributes“ function.
  • New: New toolbar on the statistics page. Added „Assign Attributes“ and „Excel export“ functions.
  • New: New function for populating the attributes of a block with the values from the statistics page for table placement. All values currently displayed on the statistics page can be matched with the corresponding attribute names.
  • New: New context menu entry „Insert attributes“ on the statistics page. This allows only the attributes of the selected node and all its subnodes to be matched. For example, specific table data can be reconciled.
  • New: The new prototype drawing „Helios 3D 2024 – Template ENU.dwg“ includes corrected table style settings that previously led to poor representations of automatically generated tables.

  • Bug: Errors occurred in yield estimation/optimization when nonsensical percentage values were entered for module parameters. These values are now only adopted if they are within the valid range; otherwise, 0.0 is used.
  • Bug: Exporting a single project did not work if the project was located in the main directory „Projects.“
  • Bug: When freezing row start points, the switch „Start rows opposite“ was not evaluated. This caused row start points to be generated at the wrong end of the respective rows.
  • Bug: For cable trenches running between two tables or very close below a table edge, the best table for connecting to the cable trench was not always found.
  • Bug: At the beginning of an exclusion area, placement gaps could occur if the table side slope and the exclusion area line were opposing.
  • Bug: If a new service pack was found and you chose to install it immediately, the installation was not started.