Introduction
-
Database Application
-
Overview of Commands
-
Layout
-
Electric
-
Evaluation
-
Data Export
-
Presentation
-
Analysis
-
===============
-
FAQ – Frequently Asked Questions
-
-
- How is the calculation of the row distance / shadow cast?
- How can I add a prototype-drawing to Helios 3D?
- What does the message “This drawing was last saved by an earlier version of one of the following products:” mean?
- How can I improve the performance of huge projects?
- Why does the Selection Dialog for Prototype Drawings not appear?
- Why are Project Numbers not Managed automatically?
-
Common Erros
-
Step-by-step Tutorials
-
Useful Hints and Tips
-
Releases
- Helios 3D Update 2026.0.1.5
- Helios 3D Update 2026.0.1.4
- Helios 3D Update 2026.0.1.3
- Helios 3D Update 2026.0.1.2
- Helios 3D Update 2026.0.1.1
- Helios 3D Update 2026.0.1.0
- Helios 3D Update 2025.0.1.4
- Helios 3D Update 2025.0.1.3
- Helios 3D Update 2025.0.1.2
- Helios 3D Update 2025.0.1.1
- Helios 3D Update 2025.0.1.0
- Helios 3D Update 2024.0.1.7
- Helios 3D Update 2024.0.1.6
- Helios 3D Update 2024.0.1.5
- Helios 3D Update 2024.0.1.4
- Helios 3D Update 2024.0.1.3
- Helios 3D Update 2024.0.1.1
- Helios 3D Update 2024.0.1.0
- View all articles ( 3 ) Collapse articles
< All Topics
Print
Helios 3D Update 2026.0.1.4
Published
Updated
New Version: 2026.0.1.4
DB Version: 2025.0.1.3
Date: 10/16/2025
Operating System: Windows 8, 8.1, 10, 11
AutoCAD: Autodesk Civil 3D 2021 to 2026
- New: A new 2D table function is now available to represent the net coverage of tables in a field as a 2D polyline.
- Change: When connecting a transformer in series to another transformer, a check is now performed to verify whether this is possible, and a message is displayed if necessary.
- Change: Previously, when target devices of strings were deleted in manual electrical planning, the connected strings were also deleted. This no longer happens.
- Bug: When selecting a cable trench, it was possible under certain circumstances to select the wrong polyline.
- Bug: When connecting a cable trench to another cable trench (not to a node), an internal error in the trench segmentation occurred. This could lead to incorrect cable paths during later wiring.
In such cases, use the „Remove cables“ function from the electrical page on the Ribbon to remove the cables from the affected cable trench. Then disconnect and reconnect the connected cable trench by moving the connection vertex away and snapping it to the target trench.
This corrects the internal segmentation, and you can then use „Rewire“ to regenerate the electrical connections. The cable paths should then be correct. - Bug: The shadow calculation only worked on one side of east-west tables.
- Bug: In the shadow calculation, shadows could sometimes appear in the opposite direction of the sun.
- Bug: With shadow calculation enabled, error messages could occur when opening a drawing or switching tabs.
- Bug: DWGs with a comma in the file name could not be opened while Civil 3D was running.
- Bug: Mirroring asymmetric strings across multiple tables could cause serious errors under certain circumstances.
- Bug: A recent change caused the palette to freeze if the insertion of a new shadow object was canceled during the naming step. Civil 3D could then only be closed via the Task Manager.